Keep Your Home Comfortable With Quality HVAC Services In Middlefield CT
X-Treme Temp Heating & Cooling is your go-to HVAC service provider in Middlefield, CT! We’re the experts in home comfort year-round, from AC and heating repair to ductwork and water heaters. We’ve got you covered from installation to maintenance so you can have peace of mind about your heating and air conditioning.
Read the reviews below from Middlefield, CT residents to see what your neighbors say about our expertise and customer service. We can’t wait to work with you!
Recent Jobs and Reviews in Middlefield, CT
Rated 4.8 out of 5 stars based on 5 customer reviews
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently praise the company for its professionalism, knowledge, and expertise in handling HVAC and heating services. A dominant theme throughout the feedback is the exceptional customer service provided, with reviewers frequently highlighting the courteous, friendly, and polite demeanor of the technicians. Many customers emphasize how thoroughly issues were explained to them, noting that their questions were answered comprehensively and that they felt well-informed throughout the service process. Fair and reasonable pricing emerges as another recurring positive sentiment, with multiple reviewers expressing satisfaction with the value received. The efficiency and quality of work are also celebrated, with customers noting timely arrivals, quick problem resolution, and work completed correctly the first time. Cleanliness and respect for customers' homes are mentioned as additional strengths. The reviews convey a strong sense of trust and loyalty, with many customers stating they would highly recommend the company and plan to use their services again in the future. Overall, the tone is enthusiastic and appreciative, reflecting a business that consistently meets and exceeds customer expectations through skilled workmanship and outstanding interpersonal service.
Middlefield, CT at a glance
X-Treme Temp Heating & Cooling, LLC has completed 25 jobs in Middlefield, CT between December 2022 and August 2026.
The 5 customer reviews shown here average 4.8 out of 5.
Service was earlier than expected, but welcomed. The two technicians were able to do the annual service. Andrew explained the service, possible future concerns, and reapplied our Annual Service Contract.
Thank you. John
John
- Middlefield, CT 06455
Considerate and helpful
Larry was a good communicator, and provided context for his recommendations. Thank you!
ruth
- Middlefield, CT 06455
Annual & check valve replacement
Service performed as expected.
John
- Middlefield, CT 06455
Great service Beaudoin
- Middlefield, CT 06455
Quick service fixed problem!
Great experience!!
Catherine
- Middlefield, CT 06455
Job Locations
Larry H.
I conducted a comprehensive preventive maintenance (PM) on an oil boiler. The process began with thorough brushing and vacuuming to remove any accumulated dust and debris. I then replaced the oil filter, nozzle, and strainer to ensure optimal performance and efficiency. After these replacements, I started the boiler and checked all safety mechanisms to confirm they were functioning correctly. A combustion test was performed, revealing an oxygen level of 4.7%, 25 ppm of CO, and an efficiency of 81.3%. These readings indicated that the system was operating within acceptable parameters. Overall, the boiler is in excellent condition and ready for continued reliable service.
Middlefield, CT 06455
Andrew H.
Performed pm on oil furnace
Brushed and vacuumed flue pipe and heat exchanger
Replaced oil filter, nozzle, and strainer
Checked all electrical connections and safeties
Performed combustion and smoke tests
8.2%o2 0ppm co 0 smoke
Middlefield, CT 06455
Andrew H.
Drained pressure from the system. Cut out and removed old purge station and male adaptor. Installed new purge station with isolation valve. Replaced circulator gaskets by the boiler. Filled system back up with water. Attempted to purge the air but found the autofeed was not allowing enough water though to force all the air out. After getting customer authorization we installed a new autofeed with backflow preventer. When attempting to remove the old autofeed the solder joint at the T snapped. Cut out and removed old 1-1/4 T and installed a new T with a 1/2 inch ball valve. Filled system back up with water and purged air out of the system. Started and tested the system. Had hot water coming back on all returns. When leaving boiler pressure was at 20 psi
Middlefield, CT 06455
Andrew H.
Brushed and vacuumed flue pipe and heat exchanger
Replaced oil filter, nozzle, and strainer
Checked all electrical connections and safeties
Performed combustion and smoke tests
Middlefield, CT 06455
Andrew H.
Brushed and vacuumed flue pipe and heat exchanger
Replaced oil filter, nozzle, and strainer
Checked all electrical connections and safeties
Performed combustion and smoke tests
8.0%o2 1ppm co 0 smoke
While performing the maintenance we found high levels of sludge at the oil filter and strainer. Recommend getting a sludge additive to help clear up any sludge in the oil tank. Also saw some minor corrosion starting to form on the oil line. The lime in the concrete is starting to make the underground oil line porous. Would recommend replacing the oil line in the future.
Middlefield, CT 06455
Larry H.
Turned system on and checked. System did not turn on. Checked the condensate pump, it was not tripped. Installed the overflow switch in the secondary drain pan. There may have been a loose wire. Checked all wires. Started and tested. Adjusted the thermostat several times and the system turned on and off properly.
Middlefield, CT 06455
Larry H.
Checked system. There was no power to the thermostat. There is a condensate pump in the attic next to the unit. When arrived, the blower door was off and the pump was unplugged. Plugged the pump in and it was in alarm due to the tank was full. It pumped the water out properly and it came out of alarm. Checked all the low voltage wires. There is an overflow switch in the secondary pan. The overflow switch is not operating properly, there is no water in the pan and it’s breaking the circuit. The overflow switch needs to be replaced. Removed the wires for the overflow temporarily to get the system running. Checked the charge, the system is low on refrigerant. Added 15 oz R410a to the system. 60*f discharge air. The system is operating properly at this time.
Need to order and return to replace the pan switch.
Middlefield, CT 06455
Andrew H.
Visually inspected indoor evap coil and blower compartment
Checked all electrical connections and safeties
Checked volts and amps
Visually inspected air filter
Rinsed condenser coil
Blew out drain line and poured water to ensure properly draining
Tested condensate pump
Checked refrigerant levels
Checked capacitor
Took temps
While performing the maintenance we found the compressor amp levels were slightly elevated for a cooler day. Would recommend replacing the unit in the near future due to age and stress on the compressor.
Middlefield, CT 06455
Larry H.
Turned the system on and the burner started, when it was up to temp the blower motor did not turn on, just buzzed. Checked the capacitor. The run capacitor is bad. Replaced the capacitor and the motor started. On start up the start winding is louder then normal, then quiets down. The motor will need to be replaced in the future.
Middlefield, CT 06455
Andrew H.
Upon arrival unit was on but not running. We found the firomatic t handle had gone bad and was not letting oil flow to the burner. Replaced the t handle and started and tested the system. Unit is working properly.
Recommend having a chimney person come and look at the entryway to the chimney liner.
Middlefield, CT 06455
Larry H.
Installed a new Reillo electric air shutter motor. Started and tested several times. System is operating properly.
Middlefield, CT 06455
Larry H.
Turned the thermostats up and the burner started and stopped. Found the air shutter was spinning and was not stopping at the end switch. Disconnected the motor and taped the end switch closed so it will fire. Cycled the burner several times.
Need to order and replace the air shutter motor.
Middlefield, CT 06455
Larry H.
Performed a heating pm on an oil furnace.
Brushed and vacuumed.
Replaced the air filter. 20x20x1
Replaced the oil filter, nozzle and strainer.
Started and checked the safeties.
Performed a combustion test. 7.0% o2, 0 ppm, 84.0% efficient
System is operating properly.
The 6” Tee flue pipe, the metal is starting to get thin and soft in a couple of spots. Recommend replacing before a hole starts to form.
Middlefield, CT 06455
Larry H.
Performed a heating pm on an oil furnace.
Brushed and vacuumed.
Replaced the oil filter, nozzle and strainer.
Started and checked the safeties.
Performed a combustion test. 5.5%o2, 1 ppm, 86.% efficient
System is operating properly.
The water heater is showing signs of a leak. Recommend replacing before it leaks water.
Middlefield, CT 06455
Andrew H.
Visually inspected indoor evap coil and blower compartment
Checked all electrical connections and safeties
Checked volts and amps
Visually inspected air filter
Rinsed condenser coil
Blew out drain line and poured water to ensure properly draining
Tested condensate pump
Checked refrigerant levels
Checked capacitor
Took temps
Middlefield, CT 06455
Larry H.
We will drain the system. Cut out and move the Zone 2 flocheck and install a flocheck for zone 3. Fill and purge all zones.
Price includes Silver Member discount.
Middlefield, CT 06455
Jonathan L.
In Middlefield, CT, during a routine HVAC system maintenance, I identified a compromised capacitor affecting the compressor's efficiency. Additionally, a blockage in the condensate drain line was found, posing a risk of water damage and reducing humidity control. The capacitor was replaced with a new unit, and the drain line was cleared of debris, ensuring the system's optimal operation and reliability.
Middlefield, CT 06455
Jonathan L.
In Middlefield, CT, I am performing comprehensive heating maintenance. Also replacing a faulty thermostat for this customer. All critical components such as air filters and coils were thoroughly inspected and cleaned, improving overall system performance. All checks were made and this client's heating system is prepared for the ongoing season.
Middlefield, CT 06455
Andrew H.
Brushed and vacuumed flue pipe and heat exchanger
Replaced oil filter, nozzle and strainer
Checked all electrical connections and safeties
Performed combustion and smoke tests
5.9%o2 20ppm co 0 smoke
Middlefield, CT 06455
Larry H.
Performed a heating pm on an oil furnace.
Brushed and vacuumed.
Replaced the oil filter, nozzle and strainer.
Replaced air filter- 20x20x1 and adjusted the blower belt.
Started and checked the safeties.
Performed a combustion test.
System is operating properly.
The blower wheel is dirty and recommend having it cleaned.
Middlefield, CT 06455
Larry H.
Performed a heating pm on an oil boiler. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Checked electrical connections and safeties. Performed a combustion test. 84% efficient. Drained the system and replaced the flo check. Filled the system and purged. After purging the system, noticed the pressure was still increasing. Valves off the autofeed and the pressure stopped increasing. Recommend replacing the auto feed.
Middlefield, CT 06455
Andrew H.
Visually inspected indoor evap coil and blower compartment
Checked all electrical connections and safeties
Checked volts and amps
Visually inspected air filter. Replaced with company supplied
Rinsed condenser coil
Blew out drain line and poured water to ensure properly draining
Tested condensate pump
Checked refrigerant levels
Checked capacitor
Took temps
Added 1.3 lbs R410A due to system being low on refrigerant. Unit is now working properly
Middlefield, CT 06455
Andrew H.
Brushed and vacuumed flu pipe and heat exchanger
Replaced oil filter, nozzle, and strainer
Checked all electrical connections and safeties
Preformed combustion and smoke tests
8.6%o2 25ppm co 0 smoke
Middlefield, CT 06455
Andrew H.
Brushed and vacuumed flu pipe and heat exchanger
Replaced oil filter, nozzle, and strainer
Checked all electrical connections and safeties
Preformed combustion and smoke tests
6,1%o2 45ppm co 0 smoke
Middlefield, CT 06455
Andrew H.
Brushed and vacuumed flu pipe and heat exchanger
Replaced oil filter, nozzle, and strainer
Checked all electrical connections and safeties
Preformed combustion and smoke tests
7.2%o2 29ppm co 0 smoke
When preforming combustion test noticed an increase in o2 of.5% indicating a crack starting to form in the heat exchanger. Recommend replacing furnace in the future before the crack leads to any heating issues.