The heating and cooling seasons are pretty equal in Waterbury, CT, which means that having a well operating heating and air conditioning system is important. To ensure that your HVAC system is operating properly, you should have it serviced twice a year and replaced once it reaches the end of its service life. Once your heating and air conditioning system reaches the end of its service life, it will not cool and heat your home effectively or efficiently. Luckily, at X-Treme Temp we can help with any HVAC need you have!
Local Reviews
for Waterbury, CT
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently praise the company for its professionalism, knowledge, and expertise in handling HVAC and heating services. A dominant theme throughout the feedback is the exceptional customer service provided, with reviewers frequently highlighting the courteous, friendly, and polite demeanor of the technicians. Many customers emphasize how thoroughly issues were explained to them, noting that their questions were answered comprehensively and that they felt well-informed throughout the service process. Fair and reasonable pricing emerges as another recurring positive sentiment, with multiple reviewers expressing satisfaction with the value received. The efficiency and quality of work are also celebrated, with customers noting timely arrivals, quick problem resolution, and work completed correctly the first time. Cleanliness and respect for customers' homes are mentioned as additional strengths. The reviews convey a strong sense of trust and loyalty, with many customers stating they would highly recommend the company and plan to use their services again in the future. Overall, the tone is enthusiastic and appreciative, reflecting a business that consistently meets and exceeds customer expectations through skilled workmanship and outstanding interpersonal service.
Our Reviews by City
Best in the business
Frank - Waterbury, CT 06704
Just doesn’t get any better. Service you can depend on.
Larry H.
Upon turning on the thermostat, the blower initiated as expected. However, the condenser was only running the fan. I inspected the capacitor, which showed no issues. Next, I verified the wires for the compressor, confirming good ohm readings. With the disconnect on and the fan operational, I noticed that only half of the contactor was receiving power, indicating a faulty contactor. I replaced the defective contactor, restarted the system, and checked the pressures. The system is now operating correctly, with both the condenser and blower functioning as intended.
Larry H.
A customer’s Weil-McLain CGa gas boiler in Waterbury was failing to distribute heat evenly throughout the home. After troubleshooting, I discovered the circulator pump had seized, preventing hot water from flowing through the radiators. I drained the system, replaced the faulty Taco 007-F5 circulator pump, and refilled the boiler while bleeding air from the system. After restarting, I monitored pressure and temperature levels to ensure smooth operation. Heat is now evenly distributed, and the system is running efficiently.
Larry H.
Performed a heating pm on an oil boiler. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Started and checked the safeties. Performed a combustion test. 6.3% o2, 0 ppm, 80.9% efficient System is operating properly.
Larry H.
Performed an A/C pm on the system. Washed the electronic air cleaner. Blew out the drain line and tested condensate pump. Rinsed the condenser coil. Checked the electrical connections, pressures and temperatures. System is operating properly.
Larry H.
Removed and replaced the ECM blower motor. Started and tested. System is operating properly.
Larry H.
Checked system. The burner turns on and heats the furnace but the fan does not start. The relay is pulled in but does not start. The fan is a variable speed motor. Plugged a test kit into the motor to check the speeds in either heat or cool but the motor did not start. The motor is bad and needs to be replaced. Need to contact the supplier.
Andrew H.
Upon arrival unit was off. Turned on and condenser turned on but air handler did not. Upon inspection found that the capacitor for the indoor blower was open internally and was not supplying the blower with power to start. After getting customer authorization we replaced the capacitor for the indoor blower and tightened the terminals on the thermostat housing. Started unit and checked refrigerant levels. Unit is operating properly and had a 19° temp difference.
Andrew H.
Brushed and vacuumed flu pipe and heat exchanger Replaced oil filter, nozzle, and strainer Checked all electrical connections and safeties Preformed combustion and smoke tests 6.9%o2 29ppm co 0 smoke Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected air filter. Replaced with customer supplied Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Tested condensate pump Checked refrigerant levels Checked capacitor Took temps Replaced capacitor after getting customer approval due to it being well outside of factory specs. Duct diagnostics 203 734 1532